Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Chim Acta ; 519: 227-230, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33989612

RESUMO

BACKGROUND AND AIMS: Glycated albumin (GA) could represent a useful biomarker in pregnant women for diagnosing and monitoring gestational diabetes mellitus (GDM). The establishment of reference intervals (RI) is mandatory before assessing its clinical usefulness. The RIs of GA in healthy pregnant women are not well defined. The aim of the current study was to establish the RI in a cohort consisting of Caucasian pregnant women without overt diabetes mellitus or gestational diabetes mellitus. METHODS: The study included 183 healthy pregnant women. GA was measured on plasma by an enzymatic method (quantILab Glycated Albumin, IL Werfen, Germany). The RI was calculated by the non-parametric and robust methods. RESULTS: The RI of GA in the whole population was 10.16% (90%CI 9.60-10.70) and 15.44% (90%CI 14.90-16.90). GA levels decreased during pregnancy, with lower levels in the third trimester: 10.11 (90%CI 9.48-10.79) and 15.72 (90%CI 15.15-16.27) in the first trimester, 10.49 (90%CI 10.05-10.96) and 15.49 (90%CI 15.05-15.92) in the second trimester, 9.84 (90%CI 9.50-10.22) and 14.57 (90%CI 14.11-15.01) in the third trimester. Finally, a weak negative correlation was found between GA levels and body mass index. CONCLUSION: This is the first study establishing the RIs of GA in Caucasian healthy pregnant women.


Assuntos
Diabetes Gestacional , Gestantes , Diabetes Gestacional/diagnóstico , Feminino , Alemanha , Produtos Finais de Glicação Avançada , Humanos , Gravidez , Albumina Sérica/análise , Albumina Sérica Glicada
2.
Clin Chem Lab Med ; 59(9): 1600-1605, 2021 08 26.
Artigo em Inglês | MEDLINE | ID: mdl-33851525

RESUMO

OBJECTIVES: In this study, we developed and evaluated the diagnostic accuracy of the Sepsis Index for early sepsis screening in the Emergency Department (ED). METHODS: Sepsis Index is based on the combination of monocyte distribution width (MDW) and mean monocyte volume (MMV). Sepsis Index≥1 was selected to define sepsis. We tested its diagnostic accuracy in an ED population stratified in four groups: controls, Systemic Inflammatory Response Syndrome (SIRS), infection, and sepsis, according to Sepsis-2 criteria. RESULTS: Patients with sepsis displayed higher median Sepsis Index value than patients without sepsis. At the receiver operating characterictis (ROC) curve analysis for the prediction of sepsis, the area under the curve (AUC) of MDW and Sepsis Index were similar: 0.966 (95%CI 0.947-0.984), and 0.964 (95%CI 0.942-0.985), respectively. Sepsis Index showed increased specificity than MDW (94.7 vs. 90.6%), without any decrease in sensitivity (92.0%). Additionally, LR+ increased from 9.8 (MDW) to 17.4 (Sepsis Index), without any substantial change in LR- (respectively 0.09 vs. 0.08). Finally, PPV increased from 0.286 (MDW) to 0.420 (Sepsis Index). CONCLUSIONS: Sepsis Index improves the diagnostic accuracy of MDW alone for sepsis screening.


Assuntos
Sepse , Área Sob a Curva , Biomarcadores , Serviço Hospitalar de Emergência , Humanos , Monócitos , Prognóstico , Curva ROC , Sepse/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...